Chokes & Inductors

DC Chokes

Product Details:
  • Start Method: Instant Start
  • Power: 250 HP
  • Voltage: 110 to 220 V
  • Brand: Procon
  • Frequency: 50 Hz
  • Usage/Application: Power Electronic Systems, Rectifier Modules

Our prudently designed DC Chokes are suitably utilized in industrial machinery power systems for filtering the power supply. These chokes are made sturdily by making use of optimum grade copper wires terminal blocks and electrical steel laminations. To ensure low power loss, the laminations used in these chokes are electrical grade CRGO. This choke range maximizes the circuit inductance in the electric and electronic circuits.

We are also dealing in Europe, Africa, and Middle East countries.


Features :

  • Excellent power filtration
  • Make sure no damage to input rectifiers from in-rush current
  • Improvise low-frequency conduction emission
  • Overload protection
  • Reduce current-voltage stress
  • Excellent protection for motor drive
  • Lowers harmonic distortion
  • Compacted design

Applications :

  • Power Electronic Systems
  • Rectifier Modules
  • Servo Drives
  • DC Bus Systems
  • Di / dt Smoothening units
  • AC Ripple Reduction Systems

AC Reactor Chokes

Product Details:
  • Ballast Type: Fluorescent Ballasts
  • Impedance: 3%, 5% & 7%
  • Start Method: Pulse Start
  • Brand: Procon
  • Certification: ISI
  • Usage/Application: Submersible pumps in oil well

AC Reactor Chokes are specially designed for lowering the cable lengths in those applications where the distance from drive to load exceeds 25 meters. Installed on the variable frequency drive, either on its input (line) or output (load) side, these reactor chokes ensure impedance matching, di/dt and harmonic mitigation. Besides this, Ac reactor chokes are also useful in the protection from the noise and surge, the transient voltage in the drives.

We are also dealing in Europe, Africa, and Middle East countries.


Features :

  • Long functional life
  • Safe to use
  • Sturdy design
  • High performance
  • Ability to reduce the current and voltage stresses on the input rectifier bridge
  • Over-voltage restriction
  • Available in single and three phases
  • Better protection of the drive
  • Improvement of low-frequency conduction emission and sensitivity

Applications :

  • 3%, 5% & 7% Impedance
  • Di / dt Protection Systems
  • 50 Hz to > 5 kHz VFD's
  • Line & Load applications
  • Submersible pumps in oil well
  • Process plants with output (load) chokes
  • VFD's - Yaskawa, Mitsubishi, Siemens, Allan Bradley, ABB, Fuji, Danfoss, LG and Control Techniques

Power Line Reactors

Product Details:
  • Type: Power Line Reactors
  • Brand: Procon
  • Reactor Type: Line Type, Load Type
  • Voltage Type: AC
  • Application: Di/Dt control for the line
  • Input Voltage: 1100V

Power Line Reactors, also known as line chokes have their prime importance in controlling the surge current for different loads. These loads include variable frequency drive, thyristor drives, robotic controllers, servo drives and various power electronic modules. In variable frequency drives, the line reactors are used for line and load di /dt protection along with controlling the speed and torque.

We are also dealing in Europe, Africa and Middle East countries.

Features :

  • Oppose rapid changes in current
  • Attenuate spikes of current
  • Limit peak currents
  • Suitable for electronic variable speed drive
  • Extra protection for Ac and DC drives
  • Reduce harmonic distortion in the input line current
  • Ensure no damage to input rectifiers from in-rush current

Applications :

  • Power electronics
  • Variable speed drives of Mitsubishi. Yaskawa, LG, Danfoss, Control Techniques, Â Fuji, ABB, Allan Bradley, Delta and Siemens
  • Thyristor Drives
  • Robotic controllers
  • Servo drives

Harmonic Mitigation Chokes

Product Details:
  • Protection System: Di / dt Protection Systems
  • Frequency: 50 Hz to 5 kHz
  • Brand: Procon
  • Core type: CRGO core
  • Application: Lighting Energy Saver
  • Impedance: 3%, 5% & 7%

Harmonics in an electrical system are very harmful, causing serious damage to the system by reducing the life of equipment and creating heat. In this way, the cable and equipments become stressed, further damaging the equipment. Harmonic Mitigation Chokes are the cost effective solution for minimizing the presence of harmonics in the electrical systems. These are basically available in three phases. In these types of chokes, these is an air gap in between, acting as an integrated choke for an additional inductance and di / dt protection to the load.

We are also dealing in Europe, Africa and Middle East
countries.


Features :

  • Reduces the harmonics in electrical systems
  • Available
  • le with three phases
  • Ensure extra inductance
  • Di/dt protection to load
  • Reduces operations and maintenance costs
  • Load side surge suppression

Applications :

  • Line & Load applications
  • Di / dt Protection Systems
  • 50 Hz to > 5 kHz VFD's
  • Process plants with output (load) chokes
  • 3%, 5% & 7% Impedance
  • Submersible pumps in oil well
  • VFD's - Yaskawa, Mitsubishi, Siemens, Allan Bradley, ABB, Fuji, Danfoss, LG and Control Techniques

VFD Line & Load Chokes

Product Details:
  • Usage: Industrial Facilities,Power Generation
  • Current Range : 1-2000 Amps
  • Type: Single/Three Phase
  • Impedance: 3%, 5% & 7%
  • Ballast Type: High Pressure Sodium Ballasts
  • Brand: Procon

VFD Line & Load Chokes are offered in different configurations of foot or flange mount with the choice in natural or forced air cooling. Easy to install on the variable frequency drives on both input (line) and output (load) side, these chokes completely ensure the impedance matching, di/dt protection, and harmonic mitigation. Using these types of chokes minimizes the damage to drives caused due to transient voltage, surge currents, and noise.

We are also dealing in Europe, Africa, and Middle East countries.

Features :

  • Can be installed on both input and output side of VFD
  • Di/dt protection
  • Offer impedance matching and harmonic mitigation
  • Complete protection to drive from transient voltage, noise and surge currents
  • Lowers the cable length requirement from drive to load
  • Can be foot or flange mounted
  • Option of natural or forced air cooling

Applications :

  • Process plants that require the output (load) chokes
  • Submersible pumps in oil well
  • Line & Load applications
  • VFD's - Yaskawa, Mitsubishi, Siemens, Allan Bradley, ABB, Fuji, Danfoss, LG and Control Techniques
  • 50 Hz to > 5 kHz VFD's
  • Process plants with output (load) chokes
  • 3%, 5% & 7% Impedance
  • Di / Dt Protection Systems
Looking for Chokes & Inductors ?
Share Us:
© Procon Controls
Desktop Site Back to top